Display Sold Separately
Measure non-conductive coatings on steel substrates.
FHXS Xtreme probe with Alumina wear face and braided cable for hot or rough surfaces.
Hot surfaces up to 250 C (500 F).Compatible with PosiTector bodies with serial numbers greater than 700,000 and the new PosiTector SmartLink.

Specifications FTS 
 | Range: | 0 - 250 mils |
0 - 6 mm |
0 - 6000 |
*Accuracy: | (0.05 mils + 1%) 0 - 2 mils |
(0.1 mils + 1%) > 2 mils |
(1 + 1%) 0 - 50 |
(2 + 1%) > 50 |
*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.

Specifications FNTS 

| Range | 0 - 250 mils |
0 - 6 mm | 0 - 6000 m |
Accuracy | (0.5 mils + 1%) 0 - 100 mils |
(0.5 mil + 3%) > 100 mils |
(0.01 mm + 1%) 0 - 2.5 mm |
(0.01 mm + 3%) > 2.5 mm |
*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.

Specifications FKS, NKS
 | Range: | 0 - 500 mils |
0 - 13 mm |
Accuracy: | (1 mils + 3%) |
(0.02 mm + 3%) |
*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.

Specifications FLS
| Probe Model | FLS |
 | Range: | 0 - 1.5 inches |
0 - 38 mm |
*Accuracy: | (0.01 in. + 3%) |
(0.2 mm + 3%) |
Minimum SurfaceArea: | 3.25 x 3.25 in. (83 x 83 mm) |
Minimum SubstrateThickness: | 0.1 in. (2.5 mm) |
*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.